+380 (97) 065-28-77
+380 (50) 147-53-58
megakad@ukr.net
Preheat room |
Upper limit preheat temperature |
200 °C |
||||
Heating time |
R.T.~+200°C, about 40min (unload) |
|||||
Precool room |
Lower limit precool temperature |
-75 °C |
||||
Cooling time |
R.T.~-70°C, about 90min (unload) |
|||||
Workroom |
Temperature shock range |
-20°C\ -40°C\ -55°C~ + 150°C |
||||
Temperature fluctuation |
<±0.5°C |
|||||
Temperature deviation |
<±3°C |
|||||
Transform time |
<15S |
|||||
Temperature revert time |
<5min |
|||||
Temperature revert conditions |
3CJ-100S |
sample load: 10kg |
Sample exposed 30min in 150℃, 5min in ambient temp. 30min in -55℃, |
|||
3CJ-210S |
sample load: 15kg |
|||||
3CJ-300S |
sample load: 25kg |
|||||
3CJ-500S |
sample load: 35kg |
|||||
Capacity |
100 L |
210 L |
300 L |
500 L |
||
Workroom dimensions (cm) |
D |
50 |
70 |
70 |
90 |
|
W |
50 |
60 |
78 |
80 |
||
H |
40 |
50 |
55 |
70 |
||
Exterior dimensions (cm) |
D |
115 |
135 |
135 |
250 |
|
W |
195 |
210 |
225 |
225 |
||
H |
210 |
220 |
230 |
215 |
||
Built-in 2 layers stainless steel plate, independent over-temperature protection, accumulated calculagraph, halogen lights, four trundle, 4 standing legs can go up or down, one down-lead hole(on left) |